For bolted cement silo with storage capacity above 300 ton, the silo diameter and height is longer, common truck, container and frame can not meet the transportation requirement, so we choose transport this cement tank by bulk parts and install the cement silo tank.
1. We have professional technician to disassemble the bolted cement silo to ensure no any damage to the cement silo body and parts.
2. To ensure the bolted cement silo quality during transportation, we adopts double package for the key parts of silo. The bolted cement tank installation is based on the order from down to up, for example: support legs-ring beam installation-hopper installation-silo body installation-feeding system installation, the detailed introduction as following:
A. Connecting the first and second section of bolted cement tank, then hanging the lifting lugs of upper section and tightening the wire rope, when holes of silo body and hopper is matched, tightening the bolts on the operating platform under ring beam.
B. Middle section of cement tank is similar with above.
C. Connecting the dust collector on the bolted cement silo roof, then installing the safety fence. During this steps, notice that the vertical reinforcement distance is below 1.2m, and the welding thickness is above 6mm with continuous and uniform state.
(5). Feeding system installation